The design readable content of a page hen looking at its layout The point our of using Movie template

Ultrafiltration

Zipped Pressure Ultrafiltration Membrane

Operating Environment

For indoor installation, avoid direct sunlight, and ensure the ambient temperature does not exceed 45℃ (113℉).


Quality Standard

Each anti-high turbidity ultrafiltration membrane undergoes testing before leaving the factory, meeting strict Zipped standards and industrial standards.


Product Introduction

  • Suitable for external pressure membrane structures with a wide turbidity range (up to 50 mg/L);

  • Advanced modification technology ensures high hydrophilicity of the membrane fibers, further enhancing the anti-pollution capability of the membrane module;

  • High filtration accuracy (actual nominal pore size of 0.07um) ensures better water quality;

  • Higher strength: The unique membrane manufacturing process enhances the strength of the ultrafiltration membrane, making it better suited to wastewater operating conditions and cleaning requirements;

  • It has a high degree of automation, is easy to operate, and simple to maintain;

  • High filling rate, small footprint;

  • The front end needs to be equipped with relevant pre-treatment equipment (sand filter, carbon filter, filter with a pore size of less than 100um, etc.)

Zipped Pressure Ultrafiltration Membrane
Product Details
ModelZWTU 2660ZWTU 2860ZWTU 2880
Membrane Area (m²)325177
Nominal Pore Size (μm)0.07
Design Flux L/m2-h40-80
Maximum Anti-wash Pressure bar2
Maximum Residual Nitrogen Concentration During Cleaning (ppm)2000(25℃)
Maximum Intake Pressure (bar)2
Normal Usage pH Range2-10
Maximum Transmembrane Pressure Difference (bar)1.5
Maximum Operating Temperature (℃)40
Maximum Inlet Pressure (bar)4
Single Film Size (mm)φ160*1975φ225*1860φ225*2360
Interface SizeWater InletDN50DN50DN50
Water Production OutletDN50DN50DN50
Concentrated Water OutletDN50DN50DN50
Air Intakeφ10φ10φ10
Tags:

Customers' Recognition Of Us

Manager of Technical Department of Municipal Water Company

"When we renovated our municipal water plant, we compared several membrane products. The anti-pollution performance of Septane membrane was amazing! After 8 months of continuous operation, the flux decay was less than 5%, and the backwash cycle was extended by 3 times. The agent followed up the water quality monit...

Technical Director of Beverage Company

"The food factory production line has strict requirements on water quality. The nanofiltration membrane has not been blocked for half a year, and even the flavor of the concentrated juice is purer. The selection scheme provided by the agent accurately matches the production capacity. Now the treatment cost per ton...

Industrial Park Water Treatment Manager

"I have been using Sept's reverse osmosis membrane for almost a year, and the desalination rate has always remained above 99%. Even high-hardness groundwater can be directly reused after treatment. The after-sales team regularly visits to test the membrane performance. When the equipment broke down last time, they...

Leave a Message

Your email address will not be published. Required fields are marked *

We are committed to protecting your privacy. We will never collect information about you without your explicit consent.